These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
2 hr fire rated wall.
Mount a 1 1 2 inch fiberglass barrier inside the studs.
There are many ways to meet the requirements for 2 hour fire rated separation walls including foundation to roof masonry walls separating the units.
Use steel studs and two layers of 1 2 inch type c drywall on each side of the studs for a two hour fire rating on an interior wall.
19 1 mm air space cover the h studs and c tracks by gypsum board battens.
An increasingly common and popular method is the gypsum area separation wall which consists of individual stud framed walls filled with fiberglass insulation for each housing unit which are separated by a special construction that consists of.
When you cannot maintain a minimum 3 4 in.
For this reason a fire rated drywall is sometimes called one hour fire wallboard.
Line or at the parapet and at the ends of walls.
Stratawall shaft wall cinema wall and securitywall.
Use special fiberglass rated for use in firewalls.
19 1 mm air space between the h stud assembly and any adjacent framing members.
Fire safety caution passing a fire test in a controlled laboratory setting and or certifying or labeling a product as having a one hour two hour or any other fire resistance or protection rating and therefore as acceptable for use in certain fire rated assemblies systems does not mean that either a particular assembly system.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
For a 2 hour fire rated assembly without the need for battens maintain a minimum 3 4 in.
For class 2 to 9 buildings including multi residential and commercial buildings gyprock fire performance solutions include.
The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels.
A wall of fire rated construction expressed in hours which serves to divide the floor area of a building into acceptable area limits as set forth in the code having jurisdiction.
A partition having an assembly of materials that will afford a given fire resistance rating expressed in hours to impede the spread of fire.
If a conventional 1 2 inch thick sheet of drywall will stand up to 30 minutes of fire then the added 1 8 inch found in the type x drywall along with its other properties will double your margin of safety to 60 minutes.
According to the engineered wood association a one hour rating indicates that a wall constructed in a manner similar to the one tested will contain flames and high temperatures and support its full load for at least one hour after the fire begins.